IMAGE INTEGRITY POLICY

Data Retention & Image Quality

Authors are responsible for retaining original, unprocessed image files and relevant metadata associated with figures submitted to the Journal of Dentistry and Oral Sciences Research (JDOSR). Original files may be requested by editors or reviewers to assess image authenticity, acquisition conditions, processing history, or the consistency of the images with the reported findings.

Authors should preserve sufficient original image data throughout the editorial process and for a reasonable period after publication, consistent with applicable institutional, ethical, and research-data requirements. Failure to provide requested original files without an adequate explanation may lead to further editorial assessment or delay in the handling of a manuscript.

Color Images Recommended minimum resolution: 300 dpi.
Grayscale Images Recommended minimum resolution: 600 dpi.
Line Art Recommended minimum resolution: 1200 dpi.

These are general recommendations. Suitability may depend on the image type, its intended presentation, and the technical requirements of the publication platform.

Image Processing & Manipulation Standards

JDOSR recognizes that appropriate image processing may be necessary for visualization, measurement, annotation, or publication-quality presentation. Processing that could influence the interpretation of scientific or clinical findings must be transparently described in the manuscript where relevant.

Authors should report relevant acquisition systems, software, processing tools, and substantive adjustments applied to images. Processing should be applied consistently and must not selectively enhance, suppress, remove, or introduce information in a way that misrepresents the underlying data. This principle applies to clinical photographs, intraoral images, dental radiographs, cone-beam computed tomography (CBCT) images, microscopy, histopathology, digital scans, and images generated by diagnostic or analytical systems.

Permitted Processing
Reasonable adjustments to brightness, contrast, color balance, cropping, or image size may be acceptable when they do not obscure, remove, or selectively emphasize scientifically or clinically relevant information. Adjustments should normally be applied consistently across the image and disclosed when they may affect interpretation. Image enhancement for readability must not alter diagnostic features or change the apparent clinical findings.
Prohibited Manipulation
Fabrication, falsification, selective alteration, inappropriate cloning, removal of relevant objects or findings, duplication of features, selective enhancement, undisclosed splicing, or any other manipulation that changes or misrepresents the underlying scientific or clinical evidence is unacceptable. Authors must not alter dental radiographs, clinical photographs, scans, or diagnostic images to conceal pathology, change treatment outcomes, or create findings that were not present in the original material.

Clinical, Dental Radiographic, Microscopy & Diagnostic Images

Clinical photographs, intraoral and extraoral images, dental radiographs, CBCT images, digital dental scans, microscopic and histopathological images, and other diagnostic visuals must accurately represent the observations described in the manuscript. Authors should avoid selecting, altering, or combining images in ways that could mislead readers about a patient's condition, diagnostic findings, treatment, or research results.

  • • Representative images should be selected according to scientifically or clinically justified criteria, with selection methods explained where necessary.
  • • Multiple views, fields, radiographic projections, scan planes, or time points should be included when necessary to support the interpretation or adequately represent the reported findings.
  • • Scale bars, magnification, staining or preparation methods, imaging settings, radiographic projection, scan parameters, and relevant diagnostic information should be provided where applicable.
  • • Composite panels should be clearly labeled. Boundaries between separately acquired images must be identifiable where scientifically relevant, and images from different patients, specimens, experiments, or time points must not be presented as though they share a common origin.
  • • Dental clinical photographs and other potentially identifiable patient images must be appropriately anonymized where possible and handled in accordance with informed-consent, confidentiality, and applicable patient-privacy requirements.
  • • Authors should check images for identifying information, including patient names, dates of birth, record numbers, labels, and embedded metadata, before submission.

Image processing must not compromise diagnostic validity. For example, changes to radiographic contrast, CBCT presentation, intraoral photographs, digital impressions, or histological images must not conceal relevant findings or exaggerate treatment effects. Any image processing that materially affects interpretation should be described in the Methods section or figure legend, as appropriate.

Image Documentation & Figure Legends

The Methods section and figure legends should provide enough information for readers to understand how images were acquired, processed, and presented. Depending on the study, relevant details may include the imaging platform, acquisition settings, software, staining or specimen-preparation methods, magnification, scale bars, radiographic or CBCT parameters, digital scanning procedures, diagnostic criteria, and substantive image-processing steps.

For clinical and case-based dental reports, figure legends should identify the relevant clinical context and sequence of images, such as pre-treatment, intraoperative, and post-treatment views, when applicable. Authors should ensure that captions accurately describe the images and do not imply findings or outcomes that the images cannot substantiate.

Original Files: Editors may request original, unprocessed images, raw image sequences, relevant metadata, acquisition records, or other supporting documentation during peer review or after publication. Authors are expected to cooperate with reasonable requests intended to assess the authenticity and integrity of submitted or published images.

Composite Figures, Splicing & Image Assembly

Composite figures may be used to present related dental, oral-science, laboratory, or clinical findings, provided their construction does not misrepresent the data. Images originating from different fields, experiments, specimens, patients, participants, time points, treatment stages, or acquisition sessions must be clearly distinguished wherever that information is relevant to interpretation.

Any non-obvious splicing, joining, or assembly of image components should be clearly indicated in the figure or figure legend. Authors must not use image assembly to conceal discontinuities, selectively exclude unfavorable observations, or create the appearance of a single continuous image, specimen, scan, or experiment when the components originate from separate sources.

When multiple radiographic views, CBCT slices, microscopic fields, clinical photographs, or digital scans are combined, the presentation must preserve their original scientific meaning. Image arrangement, labels, arrows, annotations, and other additions should clarify the findings without changing or exaggerating the evidence.

Handling Suspected Image Manipulation

Concerns about image integrity may be raised by editors, reviewers, readers, authors, institutions, or other credible sources. When a concern is identified, JDOSR may request an explanation from the corresponding author, original image files, acquisition data, processing history, relevant laboratory or clinical records, or other documentation needed to assess the concern.

The journal may assess the available evidence and seek additional expert advice where appropriate. Authors will be given a reasonable opportunity to respond to questions about their submitted material. Minor, honest, and correctable presentation errors may be addressed through replacement figures or a correction when the underlying data remain reliable and the integrity of the scientific record is not compromised.

Serious Misconduct: Where deliberate or substantial image manipulation, fabrication, or falsification is established, JDOSR may reject the manuscript, suspend publication, issue a correction or expression of concern, retract a published article, and/or notify the appropriate institution, funder, or responsible authority, as warranted by the evidence and applicable publication-ethics procedures.

Authors' Responsibility

Authors are responsible for ensuring that all submitted images accurately represent the underlying observations and have not been manipulated in a way that could mislead readers. They should maintain appropriate records of image acquisition and processing, verify the accuracy of figure labels and legends, and ensure that all co-authors review and approve the final figures.

Authors submitting clinical dental photographs, radiographs, scans, case images, or other patient-related material must also ensure that appropriate consent, confidentiality, and privacy requirements have been met. Images should be checked for direct and indirect identifiers before submission, and patient information should not be disclosed unless publication is appropriately authorized.

By submitting a manuscript to the Journal of Dentistry and Oral Sciences Research (JDOSR), authors confirm that the figures and images have been prepared in accordance with responsible research and publication practices and that original files or appropriate supporting documentation can be provided when reasonably requested by the Editorial Office.